 Document Version: V1.5

1. Product Introduction

1.1 Product Overview

The inclinometer uses a gravity acceleration sensor as its sensing element, providing high measurement accuracy. It is widely used to observe horizontal displacement changes within soil and piles in earth-rock dams, embankments, building foundations, mines, foundation pit excavation, and rock and soil slopes. It can automate tilt measurement, and by installing multiple fixed inclinometers in a borehole, tilt changes can be monitored more accurately. It is an essential precision measuring instrument for engineering construction monitoring.

The output signal type is RS485, and the communication uses the MODBUS-RTU communication protocol . The maximum communication range is 2000 meters , and secondary development is supported.

1.2 Functional Features  

n The product has a built-in reliable, high-resolution, and high-precision gravity acceleration chip.

n The product has a built-in high-precision temperature chip that provides full-range temperature compensation, effectively resisting environmental interference.

n 485 communication enables long-term automated measurement.

n It can upload data such as X-axis angle, Y-axis angle, and ambient temperature in real time.

1.4 Technical Parameters

Measurement range

± 90 °

Side rod diameter

22mm

Guide wheel spacing

500mm

General

700mm

Measurement accuracy

± 0.01 °

resolution

0.001 °

Operating voltage

Wide voltage DC10-30V

Operating temperature

-30 ℃ + 70 ℃

Water pressure resistance

Pressure at a water depth of 300m

Output signal

485

Applicable inclinometer tube inner diameter

60mm-80mm

The performance data presented above was obtained under testing conditions using our company's testing system and software. In order to continuously improve our products, our company reserves the right to change design features and specifications without prior notice.

2. Structure and working principle

2.1 Structure

① The fixed inclinometer consists of a measuring rod, guide wheel, observation cable, connecting steel wire rope, etc.

 

Structural diagram

 

Dimensions


 

② The series fixed inclinometer consists of a measuring rod, guide wheel, black waterproof line, connecting steel wire rope, etc.

 

 

 

2.2 Working Principle

2.2.1 Calculation instructions

Inclinometers calculate the horizontal displacement of the measured structure at different depths by measuring the change in the angle between the axis of the inclinometer tube and the plumb line. Multiple fixed inclinometers can be installed in series at different depths within the inclinometer tube, and the measurement data can be analyzed to determine the displacement change of the measured unit over a period of time.


 

 

 

Xi = L * ( sinθi - sinθ0 )

S = Σ X i = X 1 + X 2 + ……

L: Step size, which is the step size of a measurement point at a certain depth, and is the distance between two measurement points.

θ : The change in angle at a certain depth, the angle between the measuring rod and the plumb line.

θ0 : The offset angle of the initial position.

X: The change in displacement at a certain depth, the difference between the current position and the initial position.

S: The horizontal displacement of the measured unit.

Calculations show that the change S of the ground position relative to the previous position is equal to the sum of the displacement changes of each position at different depths relative to the initial position.

2.2.2 Data Description

After collecting the displacement data of each segment of the inclinometer, a displacement-depth curve can be plotted to visually observe the displacement change of the measured soil. The displacement of each segment is the single-point displacement change of the inclinometer at each depth, and the sum of these values is the horizontal displacement change of the measured soil.

 

3 . Equipment Installation Instructions

3.1 Equipment pre-installation inspection

Equipment list:

■ Main Equipment

■ Certificate of Conformity, Warranty Card

■ Installation accessories (steel wire rope, observation cable, 704 glue)

3.2 Equipment Installation and Precautions

Please check before installation.

Please remove the equipment from the packaging box and check whether the equipment is in good condition, whether the accessories are complete, whether the accessories are intact, and whether the label address matches the remarks.

Wiring Precautions for Series Inclinometer Equipment

If water accumulates in the oblique bore after on-site installation, waterproofing treatment must be applied to the equipment connectors. After the connectors are plugged in, they must be sealed with waterproof adhesive. The waterproof connectors between equipment should be treated as shown in the diagram below.

 

 

 

 

 

Equipment Installation Precautions

(1) Note: If water accumulates in the oblique hole after on-site installation, waterproofing treatment must be done at the equipment connector. After the connector is plugged in, waterproof sealant should be used to seal it. (Note: The cap of the plug, the connection point with the wire, and the hole should be fully coated, as shown in the picture above.)

(2) Drill holes at the location to be measured and install inclinometer tubes. When splicing and installing inclinometer tubes, the bottom should be sealed and the inclinometer tubes should be installed vertically.

(3) Backfilling can begin once the inclinometer tube installation is confirmed to be in good condition. Backfill typically uses bentonite balls or native soil and sand. Water should be injected every 3-5 meters during backfilling to ensure the bentonite balls or native soil and sand adhere firmly to the borehole wall. This process should continue until the borehole opening is reached. Exposed sections of the inclinometer tube above the ground should be protected by covering them with caps to prevent objects from falling in. The surface section of the inclinometer tube should be cast into a concrete pier to protect the stability of the opening and its corners. Observation points should be set up on the pier.

(4) When installing the inclinometer tube, the guide groove should be aligned with the measurement direction. The direction of the high guide wheel of the inclinometer is the X+ direction. When installing the inclinometer, the X+ direction should be aligned with the measurement direction and placed into the inclinometer tube along the guide groove.

(5) According to the site requirements, it is necessary to use steel wire rope or connecting screw to suspend the inclinometer in the inclinometer tube. When multiple inclinometers or series fixed inclinometers are placed, the direction of the guide wheel should be consistent. Cut the steel wire rope according to the design requirements and reserve settlement space at the bottom of the inclinometer tube.

(6) Note that the cable should be slack after it comes out, and should not be taut.

(7) After installation, the data can be read through the configuration software or uploaded to the platform for reading .

Power supply and wiring

The power input voltage is wide, DC10-30V . When wiring the 485 signal lines , ensure that lines A and B are not reversed, and that addresses do not conflict between multiple devices on the bus.

1) There are certain specifications for 485 field wiring. Please refer to the document package " 485 Equipment Field Wiring Manual " for details.

2) When devices are connected to the 485 bus , ensure that the addresses of multiple devices are not duplicated.

Specific wiring ( divided into fixed type and series type )

 

Line color

illustrate

electricity

source

Red ( brown )

Positive power supply ( wide voltage 10-30V DC)

black

Power supply negative

Pass

letter

White (yellow)

485 -A

Green ( blue )

485 -B

 

4 . Communication Protocol

4.1 Basic Communication Parameters

Editor code

8 -bit binary

Data bits

8 -bit

Parity bit

none

Stop bit

1 person

Error Validation

CRC (Cyclic Redundancy Code)

baud rate

1200 bit/s , 2400 bit/s, 4800 bit/s , 9600 bit/s , 19200 bit/s , 38400 bit/s , 57600 bit/ s , or 115200 bit/s ; the factory default is 4800 bit/s.

 

4.2 Data Frame Format Definition

The Modbus- RTU communication protocol is adopted , and the format is as follows: 

Initial structure ≥ 4 bytes of time 

Address code = 1 byte 

Function code = 1 byte 

Data area = N bytes 

Error check = 16 -bit CRC code 

End structure ≥ 4 bytes of time 

Address code: This is the address of the transmitter, which is unique in the communication network (factory default is 0x01 ).

Function code: Function indication of the command issued by the host.

Data area: The data area contains the actual communication data. Note that the high byte of the 16-bit data comes first! 

CRC code: a two-byte checksum.

Host query frame structure:

Address code

Function code

Register start address

Register length

check code low byte

high byte of check code

1 byte

1 byte

2 bytes

2 bytes

1 byte

1 byte

Slave response frame structure:

Address code

Function code

Valid byte count

Data Zone 1

Data Zone 2

Data N area

check code low byte

high byte of check code

1 byte

1 byte

1 byte

2 bytes

2 bytes

2 bytes

1 byte

1 byte

4.3 Register Address

Note that items marked with an asterisk (*) are newly added registers. Some devices do not have this register. If you require it, please contact our sales staff.

Register address

PLC or configuration address

content

operate

Definitions

00 00 H

400 0 1 (decimal)

x-axis angle

Read-only

32-bit signed integer, reads the x-axis tilt angle, magnified a thousandfold.

High position

00 01 H

400 02 (decimal)

0002H

400 03 (decimal)

y-axis angle

Read-only

32-bit signed integer, reads the y-axis tilt angle, magnified a thousandfold.

High position

0003H

400 04 ( decimal)

0004H

400 05 ( decimal)

x-axis displacement

Read-only

32-bit signed data, calculated from the X-axis angle and the length of the inclinometer beam, multiplied by 100, unit mm.

0005H

40006 ( decimal )

0006H

40007 ( decimal )

temperature

Read-only

Read the temperature value, magnify it tenfold, and use °C as the unit.

0009H

40010 (decimal)

Software version

Read-only

Software version number

00A0H

00A5H

40161 (decimal)

40166 (decimal)

Product Model

Read-only

There are six registers in total; ASC displays the product model.

00C7H

40200 (decimal)

Length of Inclined Beam

Reading and writing

Initial value 500mm, unit mm

00C8H

40201 (decimal)

x-axis deviation value

Reading and writing

32-bit signed integer, magnified a thousandfold

High position

00C9H

40202 (decimal)

00CAH

40203 (decimal)

y-axis deviation value

Reading and writing

32-bit signed integer, magnified a thousandfold , only applicable to dual-axis and triaxial sensors.

High position

00CBH

40204 (decimal)

07D0 H

42001 (decimal )

Device address

Reading and writing

1~254 (factory default 1)

07D1H

42002 (decimal)

Device baud rate

Reading and writing

0 represents 2400

1 represents 4800

2 represents 9600

3 represents 19200

4 represents 38400

5 represents 57600

6 represents 115200

7 represents 1200

07D7

42008 (decimal)

Parity check

Reading and writing

Parity 0 (no parity), parity 1 (odd parity), parity 2 (even parity). Setting numbers other than 0, 1, and 2 will be treated as having no parity (0).

005A

40090 (decimal)

Determine the initial angle

Reading and writing

Write 5A5A to determine the initial angle for displacement calculation.

 

 

4.4 Examples and Explanations of Communication Protocols

X-axis angle values at device addresses 0x00 and 0x01 .

Query Frame

Address code

Function code

Starting address

Data length

check code low byte

high byte of check code

0x 01

0x0 3

0x00 0x 00

0x00 0x0 2

0x C4

0x 0 B

Response frame

Address code

Function code

Return the number of valid bytes

x-axis angle

check code low byte

high byte of check code

0x 01

0x0 3

0x0 4

0x0 0 0x 01

0x 02 0x 34

0x AB

0x44

X-axis angle calculation:

X-axis angle : 0001 0234 H (hexadecimal) = 66100 => x-axis angle = 66.100°

Y-axis angle values from device addresses 0x02 and 0x03 .

Query Frame

Address code

Function code

Starting address

Data length

check code low byte

high byte of check code

0x 01

0x0 3

0x00 0x 02

0x00 0x0 2

0x 65

0x C B

Response frame

Address code

Function code

Return the number of valid bytes

Y-axis angle

check code low byte

high byte of check code

0x 01

0x0 3

0x0 4

0x FF 0x FF

0x 53 0x 69

0x 06

0x C9

Y-axis angle calculation:

Y-axis angle : FFFF 5369 H (hexadecimal) = -44183 => Y-axis angle = -44.183°

5 . Common problems and solutions

5.1 The device cannot connect to the PLC or computer.

Possible reasons:

1) The computer has multiple COM ports, and the wrong port was selected.

2) The device address is incorrect, or there are devices with duplicate addresses (the factory default is all 0x01 ).

3) Baud rate, parity check, data bits, stop bits errors.

4) The 485 bus is disconnected, or the A and B lines are reversed.

5) If there are too many devices or the wiring is too long, power should be supplied nearby, a 485 power booster should be added, and a 120Ω terminating resistor should be added.

6) The USB to 485 driver is not installed or is damaged.

7) Equipment damage.

 

5.2 Note

1. Warning: Risk of personal injury. This equipment must not be used as a safety device or emergency stop device, nor for any other purpose that may result in personal injury due to equipment malfunction. Usage Restrictions: Use only for the intended authorized purpose . Consult the technical manual before installation, operation, or maintenance. Failure to comply with the above guidelines may result in death or serious injury.

2. This product is a precision instrument and should be protected from drops and impacts.

3. After installation, ensure that the pull line is perpendicular to the outlet and that the wire rope is pulled out as perpendicularly as possible to ensure measurement accuracy.

4. If the instrument malfunctions due to drops or other reasons, please contact our technicians. Do not disassemble the instrument yourself.

5. Lightning protection measures should be taken for the orifice and observation cable of the guide wheel type fixed inclinometer, especially in areas with high incidence of lightning strikes.

6. Please read the equipment installation instructions and precautions carefully during the product installation process.

6. Warranty Statement

The warranty period is 24 months from the date of purchase (based on a valid proof of purchase). During the warranty period, if the equipment itself malfunctions due to problems with the materials and workmanship under normal use and maintenance, and the problem is verified, our company will provide free repair and replacement of parts.

Even after the warranty period, lifetime repair service is provided.

 

The warranty does not cover any of the following conditions:

1. The product is damaged due to incorrect installation, use, or operation.

2. Any parts of the equipment have been disassembled, repaired, modified, altered, or replaced by personnel other than our company's technicians, or by the user themselves.

3. Damage caused by negligence or by water or other substances entering the equipment.

4. Malfunctions or damages caused by unexpected events or natural disasters.